Codeunit 3688 BOM Node

Base Application, Microsoft.Inventory.BOM.Tree

src/Layers/W1/BaseApp/Inventory/BOM/Tree/BOMNode.Codeunit.al163 lines, Copyright (c) Microsoft Corporation. MIT

// ------------------------------------------------------------------------------------------------// Copyright (c) Microsoft Corporation. All rights reserved.// Licensed under the MIT License. See License.txt in the project root for license information.// ------------------------------------------------------------------------------------------------namespace Microsoft.Inventory.BOM.Tree;using Microsoft.Inventory.Item;codeunit 3688 "BOM Node"{    var        LowLevelCodeParam: Codeunit "Low-Level Code Parameter";        Type: Enum Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type";        "No.": Code[20];        ExistingLowLevelCode: Integer;        CalculatedLowLevelCode: Integer;        Initialized: Boolean;        ProdBomErr: Label 'The maximum number of BOM levels %1, was exceeded. The process stopped at %2 %3.', Comment = '%1 = max number of levels; %2 = BOM Type; %3 = BOM No.';        KeyTemplateTxt: Label '%1: %2', Comment = '%1 = Type and %2 = No.', Locked = true;    procedure GetType(): Enum Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"    begin        exit(Type);    end;    procedure GetNumber(): Code[20]    begin        exit("No.");    end;    procedure GetLowLevelCode(): Integer    begin        exit(CalculatedLowLevelCode);    end;    procedure CreateForItem(ItemNo: Code[20]; LowLevelCode: Integer; NewLowLevelCodeParam: Codeunit "Low-Level Code Parameter")    begin        Create(Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::Item, ItemNo, LowLevelCode, NewLowLevelCodeParam);    end;    procedure CreateForProdBOM(ProdBOMNo: Code[20]; LowLevelCode: Integer; NewLowLevelCodeParam: Codeunit "Low-Level Code Parameter")    begin        Create(Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::"Production BOM", ProdBOMNo, LowLevelCode, NewLowLevelCodeParam);    end;    local procedure Create(NewType: Enum Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"; NewBOMNo: Code[20]; ExistingLowLevel: Integer; NewLowLevelCodeParam: Codeunit "Low-Level Code Parameter")    begin        Type := NewType;        "No." := NewBOMNo;        ExistingLowLevelCode := ExistingLowLevel;        LowLevelCodeParam := NewLowLevelCodeParam;        Initialized := true;    end;    procedure IsInitialized(): Boolean    begin        exit(Initialized);    end;    procedure GetKey(): Text    var        JsonKey: JsonObject;    begin        JsonKey.Add('Type', Format(Type));        JsonKey.Add('No.', "No.");        exit(Format(JsonKey));    end;    procedure TraversedDown()    var        DummyParent: Codeunit "BOM Node";        Handled: Boolean;    begin        OnReachedNode(DummyParent, Handled);        if Handled then            exit;        LowLevelCodeParam.ShowDetails(StrSubstNo(KeyTemplateTxt, Type, "No."), 0, 0);        case LowLevelCodeParam.GetRunMode() of            "Low-Level Code Run Mode"::Calculate:                // this is a root                CalculatedLowLevelCode := 0;            "Low-Level Code Run Mode"::"Write To Database":                WriteToDatabase();        end;    end;    procedure TraversedDown(FromParent: Codeunit "BOM Node")    var        ParentLowLevelCode: Integer;        Handled: Boolean;    begin        OnReachedNode(FromParent, Handled);        if Handled then            exit;        LowLevelCodeParam.ShowDetails(StrSubstNo(KeyTemplateTxt, Type, "No."), 0, 0);        case LowLevelCodeParam.GetRunMode() of            "Low-Level Code Run Mode"::Calculate:                begin                    ParentLowLevelCode := FromParent.GetLowLevelCode();                    case FromParent.GetType() of                        Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::Item:                            // if parent is an item, set to at least 1 more than the parent, if not already lower                            if CalculatedLowLevelCode <= ParentLowLevelCode then                                CalculatedLowLevelCode := ParentLowLevelCode + 1;                        Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::"Production BOM":                            // if this is a production BOM, set the same low level code, if not already lower                            if CalculatedLowLevelCode < ParentLowLevelCode then                                CalculatedLowLevelCode := ParentLowLevelCode;                    end;                    if CalculatedLowLevelCode > 50 then                        Error(ProdBomErr, 50, Type, "No.")                end;            "Low-Level Code Run Mode"::"Write To Database":                WriteToDatabase();        end;    end;    local procedure WriteToDatabase()    var        Item: Record Item;    begin        if ExistingLowLevelCode = CalculatedLowLevelCode then            exit;        // Call ModifyAll instead of GET for fewer SQL callbacks        case Type of            Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::Item:                begin                    Item.SetRange("No.", "No.");                    Item.ModifyAll("Low-Level Code", CalculatedLowLevelCode);                end;            Microsoft.Manufacturing.ProductionBOM."Production BOM Line Type"::"Production BOM":                OnWriteToDatabaseOnProductionBOM("No.", CalculatedLowLevelCode);            else                OnWriteToDatabase();        end;        ExistingLowLevelCode := CalculatedLowLevelCode;    end;    [IntegrationEvent(true, false)]    local procedure OnWriteToDatabase()    begin    end;    [IntegrationEvent(true, false)]    local procedure OnReachedNode(ParentBomNode: Codeunit "BOM Node"; var Handled: Boolean)    begin    end;    [InternalEvent(false)]    local procedure OnWriteToDatabaseOnProductionBOM(BOMNo: Code[20]; CalculateLowLevelCode: Integer)    begin    end;}