Codeunit 5997 Assembly Warehouse Mgt.
src/Layers/W1/BaseApp/Assembly/Document/AssemblyWarehouseMgt.Codeunit.al286 lines, Copyright (c) Microsoft Corporation. MIT
// ------------------------------------------------------------------------------------------------// Copyright (c) Microsoft Corporation. All rights reserved.// Licensed under the MIT License. See License.txt in the project root for license information.// ------------------------------------------------------------------------------------------------namespace Microsoft.Assembly.Document;using Microsoft.Inventory.Journal;using Microsoft.Inventory.Location;using Microsoft.Warehouse.Activity;using Microsoft.Warehouse.CrossDock;using Microsoft.Warehouse.Journal;using Microsoft.Warehouse.Request;using Microsoft.Warehouse.Structure;using Microsoft.Warehouse.Worksheet;codeunit 5997 "Assembly Warehouse Mgt."{ var WhseManagement: Codeunit "Whse. Management"; WhseValidateSourceLine: Codeunit "Whse. Validate Source Line"; CannotPostConsumptionErr: Label 'You cannot post consumption for order no. %1 because a quantity of %2 remains to be picked.', Comment = '%1 - order number, %2 - quantity'; [EventSubscriber(ObjectType::Codeunit, Codeunit::"WMS Management", 'OnShowSourceDocLine', '', false, false)] local procedure OnShowSourceDocLine(SourceType: Integer; SourceSubType: Option; SourceNo: Code[20]; SourceLineNo: Integer; SourceSubLineNo: Integer) var AssemblyLine: Record "Assembly Line"; IsHandled: Boolean; begin if SourceType = Database::"Assembly Line" then begin AssemblyLine.SetRange("Document Type", SourceSubType); AssemblyLine.SetRange("Document No.", SourceNo); AssemblyLine.SetRange("Line No.", SourceLineNo); IsHandled := false; OnBeforeShowAssemblyLines(AssemblyLine, SourceSubType, SourceNo, SourceLineNo, IsHandled); if not IsHandled then PAGE.RunModal(PAGE::"Assembly Lines", AssemblyLine); end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"WMS Management", 'OnShowSourceDocCard', '', false, false)] local procedure OnShowSourceDocCard(SourceType: Integer; SourceSubType: Option; SourceNo: Code[20]) var AssemblyHeader: Record "Assembly Header"; begin if SourceType = Database::"Assembly Line" then if AssemblyHeader.Get(SourceSubType, SourceNo) then begin AssemblyHeader.SetRange("Document Type", SourceSubType); PAGE.RunModal(PAGE::"Assembly Order", AssemblyHeader); end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"WMS Management", 'OnShowWhseActivityDocLine', '', false, false)] local procedure OnAfterShowWhseActivityDocLine(WhseActivityDocType: Enum "Warehouse Activity Document Type"; WhseDocNo: Code[20]; WhseDocLineNo: Integer) begin if WhseActivityDocType = WhseActivityDocType::Assembly then ShowAssemblyLine(WhseDocNo, WhseDocLineNo); end; procedure ShowAssemblyLine(WhseDocNo: Code[20]; WhseDocLineNo: Integer) var AssemblyLine: Record "Assembly Line"; begin AssemblyLine.SetRange("Document Type", AssemblyLine."Document Type"::Order); AssemblyLine.SetRange("Document No.", WhseDocNo); AssemblyLine.SetRange("Line No.", WhseDocLineNo); PAGE.RunModal(PAGE::"Assembly Lines", AssemblyLine); end; [IntegrationEvent(false, false)] local procedure OnBeforeShowAssemblyLines(var AssemblyLine: Record "Assembly Line"; SourceSubType: Integer; SourceNo: Code[20]; SourceLineNo: Integer; var IsHandled: Boolean) begin end; procedure AssemblyLineVerifyChange(var NewAssemblyLine: Record "Assembly Line"; var OldAssemblyLine: Record "Assembly Line") var Location: Record Location; NewRecordRef: RecordRef; OldRecordRef: RecordRef; begin if OldAssemblyLine.Type <> OldAssemblyLine.Type::Item then exit; if not WhseValidateSourceLine.WhseLinesExist( DATABASE::"Assembly Line", NewAssemblyLine."Document Type".AsInteger(), NewAssemblyLine."Document No.", NewAssemblyLine."Line No.", 0, NewAssemblyLine.Quantity) then exit; NewRecordRef.GetTable(NewAssemblyLine); OldRecordRef.GetTable(OldAssemblyLine); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Document Type")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Document No.")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Line No.")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("No.")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Variant Code")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Location Code")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Unit of Measure Code")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Due Date")); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo(Quantity)); WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Quantity per")); if Location.Get(NewAssemblyLine."Location Code") and not Location."Require Shipment" then WhseValidateSourceLine.VerifyFieldNotChanged(NewRecordRef, OldRecordRef, NewAssemblyLine.FieldNo("Quantity to Consume")); OnAfterAssemblyLineVerifyChange(NewRecordRef, OldRecordRef); end; procedure AssemblyLineDelete(var AssemblyLine: Record "Assembly Line") begin if AssemblyLine.Type <> AssemblyLine.Type::Item then exit; if WhseValidateSourceLine.WhseLinesExist( DATABASE::"Assembly Line", AssemblyLine."Document Type".AsInteger(), AssemblyLine."Document No.", AssemblyLine."Line No.", 0, AssemblyLine.Quantity) then WhseValidateSourceLine.RaiseCannotBeDeletedErr(AssemblyLine.TableCaption()); OnAfterAssemblyLineDelete(AssemblyLine); end; [IntegrationEvent(false, false)] local procedure OnAfterAssemblyLineVerifyChange(var NewRecordRef: RecordRef; var OldRecordRef: RecordRef) begin end; [IntegrationEvent(false, false)] local procedure OnAfterAssemblyLineDelete(var AssemblyLine: Record "Assembly Line") begin end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Management", 'OnAfterGetSrcDocLineQtyOutstanding', '', false, false)] local procedure OnAfterGetSrcDocLineQtyOutstanding(SourceType: Integer; SourceSubType: Integer; SourceNo: Code[20]; SourceLineNo: Integer; var QtyBaseOutstanding: Decimal; var QtyOutstanding: Decimal) var AssemblyLine: Record "Assembly Line"; begin if SourceType = Database::"Assembly Line" then if AssemblyLine.Get(SourceSubType, SourceNo, SourceLineNo) then begin QtyOutstanding := AssemblyLine."Remaining Quantity"; QtyBaseOutstanding := AssemblyLine."Remaining Quantity (Base)"; end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Management", 'OnAfterGetSourceDocumentType', '', false, false)] local procedure WhseManagementGetSourceDocumentType(SourceType: Integer; SourceSubType: Integer; var SourceDocument: Enum "Warehouse Journal Source Document"; var IsHandled: Boolean) begin case SourceType of Database::"Assembly Line": begin SourceDocument := "Warehouse Journal Source Document"::"Assembly Consumption"; IsHandled := true; end; Database::"Assembly Header": begin SourceDocument := "Warehouse Journal Source Document"::"Assembly Order"; IsHandled := true; end; end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Management", 'OnAfterGetJournalSourceDocument', '', false, false)] local procedure WhseManagementGetJournalSourceDocument(SourceType: Integer; SourceSubType: Integer; var SourceDocument: Enum "Warehouse Journal Source Document"; var IsHandled: Boolean) begin case SourceType of Database::"Assembly Line": begin SourceDocument := SourceDocument::"Assembly Consumption"; IsHandled := true; end; Database::"Assembly Header": begin SourceDocument := SourceDocument::"Assembly Order"; IsHandled := true; end; end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Management", 'OnBeforeGetSourceType', '', false, false)] local procedure WhseManagementOnBeforeGetSourceType(WhseWorksheetLine: Record "Whse. Worksheet Line"; var SourceType: Integer; var IsHandled: Boolean) begin if WhseWorksheetLine."Whse. Document Type" = WhseWorksheetLine."Whse. Document Type"::Assembly then begin SourceType := Database::"Assembly Line"; IsHandled := true; end; end; [EventSubscriber(ObjectType::Report, Report::"Create Pick", 'OnCheckSourceDocument', '', false, false)] local procedure CreatePickOnCheckSourceDocument(var PickWhseWkshLine: Record "Whse. Worksheet Line") var AssemblyLine: Record "Assembly Line"; begin if PickWhseWkshLine."Source Type" = Database::"Assembly Line" then begin AssemblyLine.SetRange("Document Type", PickWhseWkshLine."Source Subtype"); AssemblyLine.SetRange("Document No.", PickWhseWkshLine."Source No."); AssemblyLine.SetRange("Line No.", PickWhseWkshLine."Source Line No."); if AssemblyLine.IsEmpty() then Error(WhseManagement.GetSourceDocumentDoesNotExistErr(), AssemblyLine.TableCaption(), AssemblyLine.GetFilters()); end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Integration Management", 'OnCheckBinTypeAndCode', '', false, false)] local procedure OnCheckBinTypeAndCode(BinType: Record "Bin Type"; AdditionalIdentifier: Option; SourceTable: Integer) begin case SourceTable of Database::"Assembly Header": BinType.AllowPutawayPickOrQCBinsOnly(); Database::"Assembly Line": BinType.AllowPutawayOrQCBinsOnly(); end; end; [EventSubscriber(ObjectType::Table, Database::"Whse. Cross-Dock Opportunity", 'OnShowReservation', '', false, false)] local procedure OnShowReservation(var WhseCrossDockOpportunity: Record "Whse. Cross-Dock Opportunity") var AssemblyLine: Record "Assembly Line"; begin case WhseCrossDockOpportunity."To Source Type" of Database::"Assembly Line": begin AssemblyLine.Get(WhseCrossDockOpportunity."To Source Subtype", WhseCrossDockOpportunity."To Source No.", WhseCrossDockOpportunity."To Source Line No."); AssemblyLine.ShowReservation(); end; end; end; [EventSubscriber(ObjectType::Table, Database::"Whse. Pick Request", 'OnLookupDocumentNo', '', false, false)] local procedure OnLookupDocumentNo(var WhsePickRequest: Record "Whse. Pick Request") var AssemblyHeader: Record "Assembly Header"; AssemblyOrders: Page "Assembly Orders"; begin case WhsePickRequest."Document Type" of WhsePickRequest."Document Type"::Assembly: begin if AssemblyHeader.Get(WhsePickRequest."Document Subtype", WhsePickRequest."Document No.") then AssemblyOrders.SetRecord(AssemblyHeader); AssemblyOrders.RunModal(); Clear(AssemblyOrders); end; end; end; [EventSubscriber(ObjectType::Codeunit, Codeunit::"Whse. Validate Source Line", 'OnItemLineVerifyChangeOnCheckEntryType', '', false, false)] local procedure OnItemLineVerifyChangeOnCheckEntryType(NewItemJnlLine: Record "Item Journal Line"; OldItemJnlLine: Record "Item Journal Line"; var LinesExist: Boolean; var QtyChecked: Boolean) var AssemblyLine: Record "Assembly Line"; Location: Record Location; QtyRemainingToBePicked: Decimal; begin case NewItemJnlLine."Entry Type" of NewItemJnlLine."Entry Type"::"Assembly Consumption": begin NewItemJnlLine.TestField("Order Type", NewItemJnlLine."Order Type"::Assembly); if Location.Get(NewItemJnlLine."Location Code") and (Location."Asm. Consump. Whse. Handling" = Location."Asm. Consump. Whse. Handling"::"Warehouse Pick (mandatory)") then if AssemblyLine.Get(AssemblyLine."Document Type"::Order, NewItemJnlLine."Order No.", NewItemJnlLine."Order Line No.") and (NewItemJnlLine.Quantity >= 0) then begin QtyRemainingToBePicked := NewItemJnlLine.Quantity - AssemblyLine."Qty. Picked"; CheckQtyRemainingToBePickedForAssemblyConsumption(NewItemJnlLine, OldItemJnlLine, QtyRemainingToBePicked); QtyChecked := true; end; LinesExist := false; end; end; end; local procedure CheckQtyRemainingToBePickedForAssemblyConsumption(var NewItemJnlLine: Record "Item Journal Line"; var OldItemJnlLine: Record "Item Journal Line"; QtyRemainingToBePicked: Decimal) var IsHandled: Boolean; begin IsHandled := false; OnBeforeCheckQtyRemainingToBePickedForAssemblyConsumption(NewItemJnlLine, OldItemJnlLine, IsHandled, QtyRemainingToBePicked); if IsHandled then exit; if QtyRemainingToBePicked > 0 then Error(CannotPostConsumptionErr, NewItemJnlLine."Order No.", QtyRemainingToBePicked); end; [IntegrationEvent(false, false)] local procedure OnBeforeCheckQtyRemainingToBePickedForAssemblyConsumption(var NewItemJnlLine: Record "Item Journal Line"; var OldItemJnlLine: Record "Item Journal Line"; var IsHandled: Boolean; var QtyRemainingToBePicked: Decimal) begin end;}