Page extension 20403 Qlty. Workflow Resp. Options
src/Apps/W1/Quality Management/app/src/Workflow/QltyWorkflowRespOptions.PageExt.al1,063 lines, Copyright (c) Microsoft Corporation. MIT
// ------------------------------------------------------------------------------------------------// Copyright (c) Microsoft Corporation. All rights reserved.// Licensed under the MIT License. See License.txt in the project root for license information.// ------------------------------------------------------------------------------------------------namespace Microsoft.QualityManagement.Workflow;using Microsoft.Foundation.AuditCodes;using Microsoft.Inventory.Item;using Microsoft.Inventory.Location;using Microsoft.Manufacturing.ProductionBOM;using Microsoft.Purchases.Vendor;using Microsoft.QualityManagement.Configuration.Template;using Microsoft.QualityManagement.Dispositions;using Microsoft.QualityManagement.Document;using Microsoft.QualityManagement.Utilities;using Microsoft.Warehouse.Structure;using System.Automation;/// <summary>/// Extend workflow response options to allow configuration of Quality Inspection Actions./// </summary>pageextension 20403 "Qlty. Workflow Resp. Options" extends "Workflow Response Options"{ layout { addlast(content) { group(Qlty_MoveInventory_Group) { Visible = QltyShouldShowInventory; ShowCaption = false; group(Qlty_MoveType) { Visible = QltyShouldShowGrpMoveType; Caption = 'Movement Method'; InstructionalText = 'Whether to use a reclassification journal or movement worksheet to process the movement.'; field(Qlty_UseReclass; QltyUseReclass) { ApplicationArea = QualityManagement; Caption = 'Use a Reclassification Journal'; ToolTip = 'Specifies that this will use an Item or Warehouse Reclassification Journal to process the movement.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyUseMoveSheet := not QltyUseReclass; QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownUseMoveSheet(), QltyUseMoveSheet); CurrPage.Update(true); end; } field(Qlty_UseMoveSheet; QltyUseMoveSheet) { ApplicationArea = QualityManagement; Caption = 'Use the Movement Worksheet (directed put-away and pick) or an Internal Movement'; ToolTip = 'Specifies that this will use the Movement Worksheet (directed put-away and pick) or an Internal Movement to process the movement.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyUseReclass := not QltyUseMoveSheet; QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownUseMoveSheet(), QltyUseMoveSheet); CurrPage.Update(true); end; } } group(Qlty_Quantity_Group) { Visible = QltyShouldShowGrpQuantity; Caption = 'Quantity'; InstructionalText = 'Choose how the system determines what quantity to move. "Entire Lot/Serial/Package" searches posted inventory entries - use this only when inventory has already been received. For workflows triggered on inspection creation (before receipt posting), use "Sample Quantity" or "Specific Quantity" instead, which read the location from the source document.'; field(Qlty_QuantityMoveAll; QltyMoveAll) { ApplicationArea = QualityManagement; Caption = 'Entire Lot/Serial/Package'; ToolTip = 'Uses all posted inventory that matches the lot, serial, or package number on the inspection and any source filters. The item and inspection must include item tracking.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll(), QltyQuantityBehavior::"Item Tracked Quantity"); if QltyMoveAll then begin QltyMoveSpecific := false; QltyUsePassed := false; QltyUseFailed := false; QltyUseTotalSample := false; QuantityToHandle := 0; QltyWorkflowResponse.SetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity(), QuantityToHandle); end; CurrPage.Update(true); end; } field(Qlty_MoveSpecific; QltyMoveSpecific) { ApplicationArea = All; Caption = 'Specific Quantity'; ToolTip = 'Uses Quantity to Handle. If it is 0, uses Quantity (Base) from the inspection. The resulting quantity must be greater than 0.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll(), QltyQuantityBehavior::"Specific Quantity"); if QltyMoveSpecific then begin QltyMoveAll := false; QltyUsePassed := false; QltyUseFailed := false; QltyUseTotalSample := false; end; CurrPage.Update(true); end; } group(Qlty_SpecificQty_Group) { ShowCaption = false; Visible = QltyMoveSpecific; field(Qlty_QuantityToHandle; QuantityToHandle) { ApplicationArea = QualityManagement; Caption = 'Quantity to Handle'; ToolTip = 'Specifies the quantity for Specific Quantity. Enter 0 to use Quantity (Base) from the inspection.'; AutoFormatType = 0; DecimalPlaces = 0 : 5; ShowMandatory = true; Enabled = QltyMoveSpecific; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity(), QuantityToHandle); end; } } group(Qlty_Sample_Group) { ShowCaption = false; field(Qlty_UseTotalSample; QltyUseTotalSample) { ApplicationArea = All; Caption = 'Sample Quantity'; ToolTip = 'Uses Sample Size from the inspection. Sample Size must be greater than 0.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll(), QltyQuantityBehavior::"Sample Quantity"); if QltyUseTotalSample then begin QltyMoveAll := false; QltyUsePassed := false; QltyUseFailed := false; QltyMoveSpecific := false; QuantityToHandle := 0; QltyWorkflowResponse.SetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity(), QuantityToHandle); end; CurrPage.Update(true); end; } field(Qlty_UsePassed; QltyUsePassed) { ApplicationArea = All; Caption = 'Passed Quantity'; ToolTip = 'Uses Passed Quantity from the inspection. Passed Quantity must be greater than 0.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll(), QltyQuantityBehavior::"Passed Quantity"); if QltyUsePassed then begin QltyMoveAll := false; QltyUseTotalSample := false; QltyUseFailed := false; QltyMoveSpecific := false; QuantityToHandle := 0; QltyWorkflowResponse.SetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity(), QuantityToHandle); end; CurrPage.Update(true); end; } field(Qlty_UseFailed; QltyUseFailed) { ApplicationArea = All; Caption = 'Failed Quantity'; ToolTip = 'Uses Failed Quantity from the inspection. Failed Quantity must be greater than 0.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll(), QltyQuantityBehavior::"Failed Quantity"); if QltyUseFailed then begin QltyMoveAll := false; QltyUseTotalSample := false; QltyUsePassed := false; QltyMoveSpecific := false; QuantityToHandle := 0; QltyWorkflowResponse.SetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity(), QuantityToHandle); end; CurrPage.Update(true); end; } } } group(Qlty_ItemTrackingChange) { Visible = QltyShouldShowGrpItemTrackingChange; Caption = 'New Item Tracking'; InstructionalText = 'Use this to change the inspected item''s tracking information, such as updating the lot no. or expiry date.'; field(Qlty_NewLotNo; NewLotNoExpression) { ApplicationArea = All; Caption = 'New Lot No.'; ToolTip = 'Specifies the new lot no. to use.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewLotNo(), NewLotNoExpression); end; trigger OnAssistEdit() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; QltyInspectionTemplateEdit: Page "Qlty. Inspection Template Edit"; Expression: Text; begin Expression := NewLotNoExpression; if QltyInspectionTemplateEdit.RunModalWith(Database::"Qlty. Inspection Header", '', Expression) in [Action::LookupOK, Action::OK, Action::Yes] then begin NewLotNoExpression := Expression; QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewLotNo(), NewLotNoExpression); end; CurrPage.Update(true); end; } field(Qlty_NewSerialNo; NewSerialNoExpression) { ApplicationArea = All; Caption = 'New Serial No.'; ToolTip = 'Specifies the new serial no. to use.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewSerialNo(), NewSerialNoExpression); end; trigger OnAssistEdit() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; QltyInspectionTemplateEdit: Page "Qlty. Inspection Template Edit"; Expression: Text; begin Expression := NewSerialNoExpression; if QltyInspectionTemplateEdit.RunModalWith(Database::"Qlty. Inspection Header", '', Expression) in [Action::LookupOK, Action::OK, Action::Yes] then begin NewSerialNoExpression := Expression; QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewSerialNo(), NewSerialNoExpression); end; CurrPage.Update(true); end; } field(Qlty_NewPackageNo; NewPackageNoExpression) { ApplicationArea = All; Caption = 'New Package No.'; ToolTip = 'Specifies the new package no. to use.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewPackageNo(), NewPackageNoExpression); end; trigger OnAssistEdit() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; QltyInspectionTemplateEdit: Page "Qlty. Inspection Template Edit"; Expression: Text; begin Expression := NewPackageNoExpression; if QltyInspectionTemplateEdit.RunModalWith(Database::"Qlty. Inspection Header", '', Expression) in [Action::LookupOK, Action::OK, Action::Yes] then begin NewPackageNoExpression := Expression; QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewPackageNo(), NewPackageNoExpression); end; CurrPage.Update(true); end; } field(Qlty_NewExpirationDate; NewExpirationDate) { ApplicationArea = All; Caption = 'New Expiration Date'; ToolTip = 'Specifies the new expiration date to use.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsDate(Rec, QltyWorkflowResponse.GetWellKnownNewExpDate(), NewExpirationDate); end; } } group(Qlty_Reason_Group) { Visible = QltyShouldShowReasonCode; Caption = 'Reason'; InstructionalText = 'Optional reason for the change.'; field(Qlty_ReasonCode; QltyReasonCode) { ApplicationArea = QualityManagement; TableRelation = "Reason Code".Code; Caption = 'Reason'; ToolTip = 'Specifies the optional reason for the change.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownReasonCode(), QltyReasonCode); end; } } group(Qlty_Source_Group) { Visible = QltyShouldShowGrpSource; Caption = 'Source (optional)'; InstructionalText = 'Optional filters that limit the inventory source. When left blank then the current location/bin that the lot/serial/package resides in will be used. When this section is filled in then this will limit the from location to only the locations and filters specified. When you are quarantining entire item tracking combinations you can leave this blank to move all existing inventory regardless of where it currently is.'; field(Qlty_SourceLocationCodeFilter; OptionalSourceLocationCodeFilter) { ApplicationArea = QualityManagement; Caption = 'Location Filter'; ToolTip = 'Specifies to optionally limit which locations will be used as the inventory source.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownSourceLocationFilter(), OptionalSourceLocationCodeFilter); end; } field(Qlty_SourceBinCodeFilter; OptionalSourceBinCodeFilter) { ApplicationArea = QualityManagement; Caption = 'Bin Filter'; ToolTip = 'Specifies to optionally limit which bins will be used as the inventory source.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownSourceBinFilter(), OptionalSourceBinCodeFilter); end; } } group(Qlty_Destination_Group) { Visible = QltyShouldShowGrpDestination; Caption = 'Destination'; field(Qlty_LocationCode; QltyLocationCode) { ApplicationArea = QualityManagement; Caption = 'Location'; ToolTip = 'Specifies the destination location to use.'; ShowMandatory = true; TableRelation = Location.Code; trigger OnValidate() var DestinationLocation: Record Location; DestinationBin: Record Bin; QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyLocation(), QltyLocationCode); QltyShowBinCode := true; if DestinationLocation.Get(QltyLocationCode) then begin QltyShowBinCode := DestinationLocation."Bin Mandatory"; if QltyBinCode <> '' then if not DestinationBin.Get(QltyLocationCode, QltyBinCode) then QltyBinCode := ''; end; end; } field(Qlty_BinCode; QltyBinCode) { ApplicationArea = QualityManagement; Caption = 'Bin'; ToolTip = 'Specifies the destination bin to use.'; ShowMandatory = true; Enabled = QltyShowBinCode; AssistEdit = true; trigger OnAssistEdit() var Bin: Record Bin; QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; BinList: Page "Bin List"; begin if QltyLocationCode <> '' then Bin.SetRange("Location Code", QltyLocationCode); BinList.SetTableView(Bin); BinList.LookupMode(true); if BinList.RunModal() in [Action::LookupOK] then begin BinList.GetRecord(Bin); QltyBinCode := Bin.Code; QltyWorkflowResponse.SetStepConfigurationValue( Rec, QltyWorkflowResponse.GetWellKnownKeyBin(), QltyBinCode); end; end; trigger OnValidate() var Bin: Record Bin; QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin // There is no table relation on this field because the bins need to be filtered by the selected location code via the OnAssistEdit trigger. // Bin is validated by fetching the record and letting it fail if it doesn't exist. Bin.Get(QltyLocationCode, QltyBinCode); QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyBin(), QltyBinCode); end; } } group(Qlty_TransferDetails_Group) { Visible = QltyShouldShowGrpTransfer; Caption = 'Transfer Details'; InstructionalText = 'If the in-transit code is blank and no Transfer Route between the locations has been defined, the transfer will be direct. If the in-transit code is blank and a Transfer Route is defined, the Transfer Route''s in-transit location will be used.'; field(Qlty_DirectTransfer; QltyDirectTransfer) { ApplicationArea = All; Caption = 'Direct Transfer'; ToolTip = 'Specifies that the transfer does not use an in-transit location'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownDirectTransfer(), QltyDirectTransfer); if QltyDirectTransfer then begin QltyInTransitLocationCode := ''; QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownInTransit(), QltyInTransitLocationCode); end; end; } field(Qlty_InTransitLocationCode; QltyInTransitLocationCode) { ApplicationArea = All; Caption = 'In-Transit Code'; ToolTip = 'Specifies the in-transit location. Leave blank for a direct transfer or to use the Transfer Route.'; TableRelation = Location.Code where("Use As In-Transit" = const(true)); Enabled = not QltyDirectTransfer; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownInTransit(), QltyInTransitLocationCode); end; } } group(Qlty_ReturnReason_Group) { Visible = QltyShouldShowGrpReturnReason; Caption = 'Return Reason (optional)'; field(Qlty_ReturnReasonCode; QltyReturnReasonCode) { ApplicationArea = QualityManagement; TableRelation = "Return Reason".Code; Caption = 'Return Reason'; ToolTip = 'Specifies the optional reason for the return.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownReasonCode(), QltyReturnReasonCode); end; } } group(Qlty_ExternalDocumentNo_Group) { Visible = QltyShouldShowGrpExternalDocNo; Caption = 'External Document'; ShowCaption = false; field(ExternalDocumentNo; ExternalDocumentNo) { ApplicationArea = QualityManagement; Caption = 'Vendor Credit Memo No.'; ToolTip = 'Specifies the optional Vendor Credit Memo No.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownExternalDocNo(), ExternalDocumentNo); end; } } group(Qlty_PostImmediately_Group) { Visible = QltyShouldShowGrpPosting; Caption = 'Post/Release Now or Later'; InstructionalText = 'Posting immediately can impact the Business Central licensing requirements.'; group(Qlty_CreatePutAway_Group) { ShowCaption = false; Visible = QltyShouldShowCreatePutaway; field(Qlty_CreatePutAway; QltyCreatePutAway) { ApplicationArea = QualityManagement; Caption = 'Create the Put-away'; ToolTip = 'Specifies to automatically create the Put-away from the Internal Put-away. Use the Just Create Entries option to only create the Internal Put-away.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin if QltyCreatePutAway then begin QltyPostImmediately := false; QltyPostLater := false; end; if QltyShouldShowCreatePutaway and not QltyPostImmediately and not QltyPostLater then QltyCreatePutAway := true; QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownCreatePutAway(), QltyCreatePutAway); QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownPostImmediately(), QltyPostImmediately); end; } } field(Qlty_PostNow; QltyPostImmediately) { ApplicationArea = QualityManagement; Caption = 'Post Immediately'; ToolTip = 'Specifies to post the journal or create the movement document immediately.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin if QltyPostImmediately then begin QltyCreatePutAway := false; QltyPostLater := false; QltyItemAdjPostBehavior := QltyItemAdjPostBehavior::Post; end; if QltyItemAdjPostBehavior = QltyItemAdjPostBehavior::Post then QltyPostImmediately := true; QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownPostImmediately(), QltyPostImmediately); QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownCreatePutAway(), QltyCreatePutAway); QltyWorkflowResponse.SetStepConfigurationValueAsAdjPostingEnum(Rec, QltyWorkflowResponse.GetWellKnownAdjPostingBehavior(), QltyItemAdjPostBehavior); end; } field(Qlty_PostLater; QltyPostLater) { ApplicationArea = QualityManagement; Caption = 'Just Create Entries'; ToolTip = 'Specifies to just create the journal or movement entries.'; trigger OnValidate() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin if QltyPostLater then begin QltyCreatePutAway := false; QltyPostImmediately := false; QltyItemAdjPostBehavior := QltyItemAdjPostBehavior::"Prepare only"; end; if QltyItemAdjPostBehavior = QltyItemAdjPostBehavior::"Prepare only" then QltyPostLater := true; QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownPostImmediately(), QltyPostImmediately); QltyWorkflowResponse.SetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownCreatePutAway(), QltyCreatePutAway); QltyWorkflowResponse.SetStepConfigurationValueAsAdjPostingEnum(Rec, QltyWorkflowResponse.GetWellKnownAdjPostingBehavior(), QltyItemAdjPostBehavior); end; } } } group(Qlty_SetDatabaseValue_Group) { ShowCaption = false; Visible = QltyShouldShowSetDatabaseValue; InstructionalText = 'Set a field value in a table.'; group(Qlty_SetDatabaseValue_Examples_Group) { Caption = 'Examples:'; field(Qlty_SetDatabaseTable_Helper1; 'Block purchase on item card.') { ApplicationArea = QualityManagement; ShowCaption = false; Editable = false; Caption = ' '; ToolTip = 'Select to populate the fields with an example that blocks purchases on the item card.'; trigger OnDrillDown() var Item: Record Item; begin DatabaseTableName := Item.TableName(); DatabaseTableFilter := 'WHERE(No.=FILTER([Item:No.]))'; TestFieldToSet := Item.FieldName("Purchasing Blocked"); TestValueExpressionToSet := 'All'; Qlty_SetCommonDatabaseVariables(); end; } field(Qlty_SetDatabaseTable_Helper2; 'Block vendor.') { ApplicationArea = QualityManagement; ShowCaption = false; Editable = false; Caption = ' '; ToolTip = 'Select to populate the fields with an example that blocks a vendor.'; trigger OnDrillDown() var Vendor: Record Vendor; begin DatabaseTableName := Vendor.TableName(); DatabaseTableFilter := 'WHERE(No.=FILTER([Vendor:No.]))'; TestFieldToSet := Vendor.FieldName("Blocked"); TestValueExpressionToSet := 'true'; Qlty_SetCommonDatabaseVariables(); end; } field(Qlty_SetDatabaseTable_Helper3; 'Flag BOM as under development.') { ApplicationArea = Manufacturing; ShowCaption = false; Editable = false; Caption = ' '; ToolTip = 'Select to populate the fields with an example that flags a BOM as under development.'; trigger OnDrillDown() var ProductionBOMHeader: Record "Production BOM Header"; begin DatabaseTableName := ProductionBOMHeader.TableName(); DatabaseTableFilter := 'WHERE(No.=FILTER([BOM:No.]))'; TestFieldToSet := ProductionBOMHeader.FieldName("Status"); TestValueExpressionToSet := UnderDevelopmentTxt; Qlty_SetCommonDatabaseVariables(); end; } } group(Qlty_SetDatabaseConfiguration_Group) { Caption = 'Configuration:'; field(Qlty_SetDatabaseTable; DatabaseTableName) { ApplicationArea = QualityManagement; Caption = 'Table'; Tooltip = 'Specifies which table to set?'; trigger OnValidate() var QltyFilterHelpers: Codeunit "Qlty. Filter Helpers"; CurrentTable: Integer; begin if DatabaseTableName <> '' then begin CurrentTable := QltyFilterHelpers.IdentifyTableIDFromText(DatabaseTableName); if CurrentTable = 0 then QltyFilterHelpers.RunModalLookupTableFromText(DatabaseTableName); end; Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; trigger OnAssistEdit() var QltyFilterHelpers: Codeunit "Qlty. Filter Helpers"; begin QltyFilterHelpers.RunModalLookupTableFromText(DatabaseTableName); Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; } field(Qlty_SetDatabaseFilter; DatabaseTableFilter) { ApplicationArea = QualityManagement; Caption = 'Filter'; Tooltip = 'Specifies what filter to use to find the record.'; trigger OnValidate() begin Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; trigger OnAssistEdit() var QltyFilterHelpers: Codeunit "Qlty. Filter Helpers"; CurrentTable: Integer; begin CurrentTable := QltyFilterHelpers.IdentifyTableIDFromText(DatabaseTableName); if CurrentTable = 0 then Error(QltyChooseTableFirstErr); QltyFilterHelpers.BuildFilter(CurrentTable, true, DatabaseTableFilter); Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; } field(Qlty_SetDatabaseField; TestFieldToSet) { ApplicationArea = QualityManagement; Caption = 'Field'; Tooltip = 'Specifies which field on the table to set? [QltyInspectionField] nomenclature can be used to help find record based on another value in the quality inspection.'; InstructionalText = '[QltyInspectionField] nomenclature can be used to help find record based on another value in the quality inspection.'; trigger OnValidate() var QltyFilterHelpers: Codeunit "Qlty. Filter Helpers"; CurrentField: Integer; CurrentTable: Integer; begin if TestFieldToSet <> '' then begin CurrentTable := QltyFilterHelpers.IdentifyTableIDFromText(DatabaseTableName); if CurrentTable = 0 then Error(QltyChooseTableFirstErr); CurrentField := QltyFilterHelpers.IdentifyFieldIDFromText(CurrentTable, TestFieldToSet); if CurrentField = 0 then QltyFilterHelpers.RunModalLookupFieldFromText(DatabaseTableName, TestFieldToSet); end; Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; trigger OnAssistEdit() var QltyFilterHelpers: Codeunit "Qlty. Filter Helpers"; begin QltyFilterHelpers.RunModalLookupFieldFromText(DatabaseTableName, TestFieldToSet); Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; } field(Qlty_SetDatabaseValue; TestValueExpressionToSet) { ApplicationArea = QualityManagement; Caption = 'Value to Set'; Tooltip = 'Specifies what value do you want to set? [QltyInspectionField] nomenclature can be used to use a field on the quality inspection while setting the value.'; InstructionalText = '[QltyInspectionField] nomenclature can be used to use a field on the quality inspection while setting the value.'; trigger OnValidate() begin Qlty_SetCommonDatabaseVariables(); CurrPage.Update(true); end; trigger OnAssistEdit() var QltyInspectionTemplateEdit: Page "Qlty. Inspection Template Edit"; Expression: Text; begin Expression := TestValueExpressionToSet; if QltyInspectionTemplateEdit.RunModalWith(Database::"Qlty. Inspection Header", '', Expression) in [Action::LookupOK, Action::OK, Action::Yes] then begin TestValueExpressionToSet := Expression; Qlty_SetCommonDatabaseVariables(); end; CurrPage.Update(true); end; } } } } } var QltyShouldShowSetDatabaseValue: Boolean; QltyLocationCode: Code[10]; QltyBinCode: Code[20]; QltyMoveAll: Boolean; QltyPostImmediately: Boolean; QltyPostLater: Boolean; QltyShowBinCode: Boolean; QltyCreatePutAway: Boolean; QuantityToHandle: Decimal; OptionalSourceLocationCodeFilter: Text; OptionalSourceBinCodeFilter: Text; QltyUseReclass: Boolean; QltyUseMoveSheet: Boolean; TestFieldToSet: Text; TestValueExpressionToSet: Text; DatabaseTableName: Text; DatabaseTableFilter: Text; QltyUseTotalSample: Boolean; QltyUseFailed: Boolean; QltyUsePassed: Boolean; QltyMoveSpecific: Boolean; QltyQuantityBehavior: Enum "Qlty. Quantity Behavior"; QltyShouldShowCreatePutaway: Boolean; QltyShouldShowInventory: Boolean; QltyShouldShowGrpMoveType: Boolean; QltyShouldShowGrpQuantity: Boolean; QltyShouldShowGrpSource: Boolean; QltyShouldShowGrpDestination: Boolean; QltyShouldShowGrpPosting: Boolean; QltyShouldShowGrpRegWhseJrnl: Boolean; QltyShouldShowReasonCode: Boolean; QltyItemAdjPostBehavior: Enum "Qlty. Item Adj. Post Behavior"; QltyShouldShowGrpItemTrackingChange: Boolean; NewLotNoExpression, NewSerialNoExpression, NewPackageNoExpression : Text; NewExpirationDate: Date; QltyReasonCode: Code[10]; QltyReturnReasonCode: Code[10]; QltyDirectTransfer: Boolean; QltyInTransitLocationCode: Code[10]; QltyShouldShowGrpTransfer: Boolean; ExternalDocumentNo: Text; QltyShouldShowGrpReturnReason: Boolean; QltyShouldShowGrpExternalDocNo: Boolean; QltyChooseTableFirstErr: Label 'Please choose a valid table first.'; UnderDevelopmentTxt: Label 'Under Development', Comment = 'Text value to set a Production BOM Header to Under Development status.'; trigger OnAfterGetRecord() begin Qlty_SetGroupVisibility(); Qlty_SetFields(); end; /// <summary> /// Stores the database table, filter, field, and value expression configuration. /// </summary> local procedure Qlty_SetCommonDatabaseVariables() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyDatabaseTable(), DatabaseTableName); QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyDatabaseTableFilter(), DatabaseTableFilter); QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyField(), TestFieldToSet); QltyWorkflowResponse.SetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyValueExpression(), TestValueExpressionToSet); end; /// <summary> /// Sets the quantity behavior Boolean fields from the selected quantity behavior. /// </summary> local procedure Qlty_SetMoveBehaviorBools() begin QltyMoveSpecific := false; QltyMoveAll := false; QltyUseTotalSample := false; QltyUsePassed := false; QltyUseFailed := false; case QltyQuantityBehavior of QltyQuantityBehavior::"Specific Quantity": QltyMoveSpecific := true; QltyQuantityBehavior::"Item Tracked Quantity": QltyMoveAll := true; QltyQuantityBehavior::"Sample Quantity": QltyUseTotalSample := true; QltyQuantityBehavior::"Passed Quantity": QltyUsePassed := true; QltyQuantityBehavior::"Failed Quantity": QltyUseFailed := true; end; end; /// <summary> /// Sets response option group visibility for the current workflow response function. /// </summary> local procedure Qlty_SetGroupVisibility() var QltyWorkflowSetup: Codeunit "Qlty. Workflow Setup"; begin QltyShouldShowInventory := false; QltyShouldShowGrpMoveType := false; QltyShouldShowGrpQuantity := false; QltyShouldShowGrpSource := false; QltyShouldShowGrpDestination := false; QltyShouldShowGrpPosting := false; QltyShouldShowCreatePutaway := false; QltyShouldShowSetDatabaseValue := false; QltyShouldShowGrpRegWhseJrnl := false; QltyShouldShowGrpItemTrackingChange := false; QltyShouldShowReasonCode := false; QltyShouldShowGrpTransfer := false; QltyShowBinCode := false; case Rec."Response Function Name" of QltyWorkflowSetup.GetWorkflowResponseMoveInventory(): begin QltyShouldShowInventory := true; QltyShouldShowGrpMoveType := true; QltyShouldShowGrpQuantity := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpDestination := true; QltyShouldShowGrpPosting := true; end; QltyWorkflowSetup.GetWorkflowResponseInternalPutAway(): begin QltyShouldShowInventory := true; QltyShouldShowGrpQuantity := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpPosting := true; QltyShouldShowCreatePutaway := true; end; QltyWorkflowSetup.GetWorkflowResponseSetDatabaseValue(): QltyShouldShowSetDatabaseValue := true; QltyWorkflowSetup.GetWorkflowResponseInventoryAdjustment(): begin QltyShouldShowInventory := true; QltyShouldShowGrpQuantity := true; QltyShouldShowReasonCode := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpPosting := true; QltyShouldShowGrpRegWhseJrnl := true; end; QltyWorkflowSetup.GetWorkflowResponseChangeItemTracking(): begin QltyShouldShowInventory := true; QltyShouldShowGrpQuantity := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpPosting := true; QltyShouldShowGrpItemTrackingChange := true; end; QltyWorkflowSetup.GetWorkflowResponseCreateTransfer(): begin QltyShouldShowInventory := true; QltyShouldShowGrpQuantity := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpDestination := true; QltyShouldShowGrpTransfer := true; end; QltyWorkflowSetup.GetWorkflowResponseCreatePurchaseReturn(): begin QltyShouldShowInventory := true; QltyShouldShowGrpQuantity := true; QltyShouldShowGrpSource := true; QltyShouldShowGrpReturnReason := true; QltyShouldShowGrpExternalDocNo := true; end; end; end; /// <summary> /// Loads visible response option fields from workflow step configuration. /// </summary> local procedure Qlty_SetFields() var QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin if QltyShouldShowInventory then begin if QltyShouldShowGrpMoveType then begin QltyUseMoveSheet := QltyWorkflowResponse.GetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownUseMoveSheet()); QltyUseReclass := not QltyUseMoveSheet; end; if QltyShouldShowGrpQuantity then begin QuantityToHandle := QltyWorkflowResponse.GetStepConfigurationValueAsDecimal(Rec, QltyWorkflowResponse.GetWellKnownKeyQuantity()); QltyQuantityBehavior := QltyWorkflowResponse.GetStepConfigurationValueAsQuantityBehaviorEnum(Rec, QltyWorkflowResponse.GetWellKnownMoveAll()); Qlty_SetMoveBehaviorBools(); end; if QltyShouldShowGrpSource then begin OptionalSourceLocationCodeFilter := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownSourceLocationFilter()); OptionalSourceBinCodeFilter := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownSourceBinFilter()); end; if QltyShouldShowGrpDestination then SetLocationAndBinCode(); if QltyShouldShowGrpPosting then begin QltyCreatePutAway := QltyWorkflowResponse.GetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownCreatePutAway()); QltyPostImmediately := QltyWorkflowResponse.GetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownPostImmediately()); if not QltyCreatePutAway and not QltyPostImmediately then QltyPostLater := true; if not QltyCreatePutAway and QltyPostImmediately then QltyPostLater := false; end; end; if QltyShouldShowSetDatabaseValue then begin TestFieldToSet := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyField()); TestValueExpressionToSet := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyValueExpression()); end; if QltyShouldShowSetDatabaseValue then begin DatabaseTableName := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyDatabaseTable()); DatabaseTableFilter := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownKeyDatabaseTableFilter()); end; if QltyShouldShowGrpRegWhseJrnl then begin QltyItemAdjPostBehavior := QltyWorkflowResponse.GetStepConfigurationValueAsAdjPostingEnum(Rec, QltyWorkflowResponse.GetWellKnownAdjPostingBehavior()); case QltyItemAdjPostBehavior of QltyItemAdjPostBehavior::"Prepare only": begin QltyPostLater := true; QltyPostImmediately := false; end; QltyItemAdjPostBehavior::Post: begin QltyPostImmediately := true; QltyPostLater := false; end; end; end; if QltyShouldShowGrpItemTrackingChange then begin NewLotNoExpression := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewLotNo()); NewSerialNoExpression := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewSerialNo()); NewPackageNoExpression := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownNewPackageNo()); NewExpirationDate := QltyWorkflowResponse.GetStepConfigurationValueAsDate(Rec, QltyWorkflowResponse.GetWellKnownNewExpDate()); end; if QltyShouldShowReasonCode then QltyReasonCode := QltyWorkflowResponse.GetStepConfigurationValueAsCode10(Rec, QltyWorkflowResponse.GetWellKnownReasonCode()); if QltyShouldShowGrpReturnReason then QltyReturnReasonCode := QltyWorkflowResponse.GetStepConfigurationValueAsCode10(Rec, QltyWorkflowResponse.GetWellKnownReasonCode()); if QltyShouldShowGrpExternalDocNo then ExternalDocumentNo := QltyWorkflowResponse.GetStepConfigurationValue(Rec, QltyWorkflowResponse.GetWellKnownExternalDocNo()); if QltyShouldShowGrpTransfer then begin QltyDirectTransfer := QltyWorkflowResponse.GetStepConfigurationValueAsBoolean(Rec, QltyWorkflowResponse.GetWellKnownDirectTransfer()); QltyInTransitLocationCode := QltyWorkflowResponse.GetStepConfigurationValueAsCode10(Rec, QltyWorkflowResponse.GetWellKnownInTransit()); end; end; /// <summary> /// Loads the destination location and bin and sets bin visibility from the location setup. /// </summary> local procedure SetLocationAndBinCode() var Location: Record Location; QltyWorkflowResponse: Codeunit "Qlty. Workflow Response"; begin QltyLocationCode := QltyWorkflowResponse.GetStepConfigurationValueAsCode10(Rec, QltyWorkflowResponse.GetWellKnownKeyLocation()); QltyBinCode := QltyWorkflowResponse.GetStepConfigurationValueAsCode20(Rec, QltyWorkflowResponse.GetWellKnownKeyBin()); QltyShowBinCode := true; if Location.Get(QltyLocationCode) then; QltyShowBinCode := Location."Bin Mandatory"; end;}