Report 20409 Qlty. Change Item Tracking
src/Apps/W1/Quality Management/app/src/Dispositions/ItemTracking/QltyChangeItemTracking.Report.al299 lines, Copyright (c) Microsoft Corporation. MIT
// ------------------------------------------------------------------------------------------------// Copyright (c) Microsoft Corporation. All rights reserved.// Licensed under the MIT License. See License.txt in the project root for license information.// ------------------------------------------------------------------------------------------------namespace Microsoft.QualityManagement.Dispositions.ItemTracking;using Microsoft.Inventory.Location;using Microsoft.QualityManagement.Dispositions;using Microsoft.QualityManagement.Document;using Microsoft.Warehouse.Structure;/// <summary>/// Use this to update item tracking information./// </summary>report 20409 "Qlty. Change Item Tracking"{ Caption = 'Quality Management - Change Item Tracking'; AdditionalSearchTerms = 'Change lot number, Change serial number, Change package number, Change Expiration Date'; ToolTip = 'Use this to update item tracking information.'; ProcessingOnly = true; AccessByPermission = tabledata "Qlty. Inspection Header" = R; UsageCategory = Tasks; ApplicationArea = QualityManagement; AllowScheduling = false; Extensible = true; dataset { dataitem(CurrentInspection; "Qlty. Inspection Header") { RequestFilterFields = "No.", "Re-inspection No.", "Source Item No.", "Source Variant Code", "Source Lot No.", "Source Serial No.", "Source Package No.", "Source Document No.", "Template Code"; trigger OnAfterGetRecord() var TempInstructionQltyDispositionBuffer: Record "Qlty. Disposition Buffer" temporary; ReactionTrkngQltyDispChangeTracking: Codeunit "Qlty. Disp. Change Tracking"; begin TempInstructionQltyDispositionBuffer."Qty. To Handle (Base)" := SpecificQuantity; TempInstructionQltyDispositionBuffer."Quantity Behavior" := QltyQuantityBehavior; TempInstructionQltyDispositionBuffer."Location Filter" := FilterOfSourceLocationCode; TempInstructionQltyDispositionBuffer."Bin Filter" := FilterOfSourceBinCode; if ShouldPostNow then TempInstructionQltyDispositionBuffer."Entry Behavior" := TempInstructionQltyDispositionBuffer."Entry Behavior"::Post; TempInstructionQltyDispositionBuffer."New Lot No." := NewLotNo; TempInstructionQltyDispositionBuffer."New Serial No." := NewSerialNo; TempInstructionQltyDispositionBuffer."New Package No." := NewPackageNo; TempInstructionQltyDispositionBuffer."New Expiration Date" := NewExpirationDate; ReactionTrkngQltyDispChangeTracking.PerformDisposition(CurrentInspection, TempInstructionQltyDispositionBuffer); end; } } requestpage { AboutTitle = 'About Changing Item Tracking'; AboutText = 'Use this to change the inspected item''s tracking information, such as updating the lot no. or expiry date.'; layout { area(Content) { group(Quantity) { Caption = 'Quantity'; InstructionalText = 'The quantity of the item to be reclassified.'; field(ChooseReclassTracked; IsReclassTracked) { ApplicationArea = ItemTracking; Caption = 'Entire Lot/Serial/Package'; ToolTip = 'Uses all posted inventory that matches the lot, serial, or package number on the inspection and any source filters. The item and inspection must include item tracking.'; trigger OnValidate() begin if IsReclassTracked then begin QltyQuantityBehavior := QltyQuantityBehavior::"Item Tracked Quantity"; IsReclassSpecific := false; IsReclassSampleSize := false; IsReclassPassed := false; IsReclassFailed := false; end else if QltyQuantityBehavior = QltyQuantityBehavior::"Item Tracked Quantity" then IsReclassTracked := true; CurrReport.RequestOptionsPage.Update(true); end; } field(ChooseReclassSpecificQuantity; IsReclassSpecific) { ApplicationArea = ItemTracking; Caption = 'Specific Quantity'; ToolTip = 'Uses Quantity to Handle. If it is 0, uses Quantity (Base) from the inspection. The resulting quantity must be greater than 0.'; trigger OnValidate() begin if IsReclassSpecific then begin QltyQuantityBehavior := QltyQuantityBehavior::"Specific Quantity"; IsReclassTracked := false; IsReclassSampleSize := false; IsReclassPassed := false; IsReclassFailed := false; end else if QltyQuantityBehavior = QltyQuantityBehavior::"Specific Quantity" then IsReclassSpecific := true; CurrReport.RequestOptionsPage.Update(true); end; } group(SpecificQty) { ShowCaption = false; Visible = IsReclassSpecific; field(ChooseQuantity; SpecificQuantity) { ApplicationArea = ItemTracking; Caption = 'Quantity to Handle'; ToolTip = 'Specifies the quantity for Specific Quantity. Enter 0 to use Quantity (Base) from the inspection.'; AutoFormatType = 0; DecimalPlaces = 0 : 5; Enabled = IsReclassSpecific; } } field(ChooseReclassSampleSize; IsReclassSampleSize) { ApplicationArea = ItemTracking; Caption = 'Sample Quantity'; ToolTip = 'Uses Sample Size from the inspection. Sample Size must be greater than 0.'; trigger OnValidate() begin if IsReclassSampleSize then begin QltyQuantityBehavior := QltyQuantityBehavior::"Sample Quantity"; IsReclassTracked := false; IsReclassSpecific := false; IsReclassPassed := false; IsReclassFailed := false; end else if QltyQuantityBehavior = QltyQuantityBehavior::"Sample Quantity" then IsReclassSampleSize := true; CurrReport.RequestOptionsPage.Update(true); end; } field(ChooseReclassSamplePass; IsReclassPassed) { ApplicationArea = ItemTracking; Caption = 'Passed Quantity'; ToolTip = 'Uses Passed Quantity from the inspection. Passed Quantity must be greater than 0.'; trigger OnValidate() begin if IsReclassPassed then begin QltyQuantityBehavior := QltyQuantityBehavior::"Passed Quantity"; IsReclassTracked := false; IsReclassSpecific := false; IsReclassSampleSize := false; IsReclassFailed := false; end else if QltyQuantityBehavior = QltyQuantityBehavior::"Passed Quantity" then IsReclassPassed := true; CurrReport.RequestOptionsPage.Update(true); end; } field(ChooseReclassSampleFail; IsReclassFailed) { ApplicationArea = ItemTracking; Caption = 'Failed Quantity'; ToolTip = 'Uses Failed Quantity from the inspection. Failed Quantity must be greater than 0.'; trigger OnValidate() begin if IsReclassFailed then begin QltyQuantityBehavior := QltyQuantityBehavior::"Failed Quantity"; IsReclassTracked := false; IsReclassSpecific := false; IsReclassSampleSize := false; IsReclassPassed := false; end else if QltyQuantityBehavior = QltyQuantityBehavior::"Failed Quantity" then IsReclassFailed := true; CurrReport.RequestOptionsPage.Update(true); end; } } group(ReclassType) { Caption = 'Item Tracking'; field(ChooseNewLotNo; NewLotNo) { ApplicationArea = ItemTracking; Caption = 'New Lot No.'; ToolTip = 'Specifies the new lot no. to use.'; } field(ChooseNewSerialNo; NewSerialNo) { ApplicationArea = ItemTracking; Caption = 'New Serial No.'; ToolTip = 'Specifies the new serial no. to use.'; } field(ChooseNewPackageNo; NewPackageNo) { ApplicationArea = ItemTracking; Caption = 'New Package No.'; ToolTip = 'Specifies the new package no. to use.'; } field(ChooseNewExpiration; NewExpirationDate) { ApplicationArea = ItemTracking; Caption = 'New Expiration Date'; ToolTip = 'Specifies the new expiration date to use.'; } } group(Source) { Caption = 'Source (optional)'; InstructionalText = 'Optional filters that limit which inventory is updated if the inspected item is in more than one location or bin.'; field(ChooseSourceLocationFilter; FilterOfSourceLocationCode) { ApplicationArea = All; TableRelation = Location.Code; Caption = 'Location Filter'; ToolTip = 'Specifies to optionally limit which locations will be used to pull the inventory from.'; } field(ChooseSourceBinFilter; FilterOfSourceBinCode) { ApplicationArea = All; TableRelation = Bin.Code; Caption = 'Bin Filter'; ToolTip = 'Specifies to optionally limit which bins will be used to pull the inventory from.'; } } group(PostImmediately) { Caption = 'Post Now or Later'; field(ChoosePostNow; ShouldPostNow) { ApplicationArea = All; Caption = 'Post Immediately'; ToolTip = 'Specifies to post the journal immediately.'; trigger OnValidate() begin ShouldPostLater := not ShouldPostNow; end; } field(ChoosePostLater; ShouldPostLater) { ApplicationArea = All; Caption = 'Just Create Entries'; ToolTip = 'Specifies to just create the journal entries.'; trigger OnValidate() begin ShouldPostNow := not ShouldPostLater; end; } } } } } var QltyQuantityBehavior: Enum "Qlty. Quantity Behavior"; NewLotNo, NewSerialNo, NewPackageNo : Code[50]; NewExpirationDate: Date; SpecificQuantity: Decimal; FilterOfSourceLocationCode: Code[100]; FilterOfSourceBinCode: Code[100]; IsReclassTracked: Boolean; IsReclassSpecific: Boolean; IsReclassSampleSize: Boolean; IsReclassPassed: Boolean; IsReclassFailed: Boolean; ShouldPostNow: Boolean; ShouldPostLater: Boolean; NoItemTrackingChangesErr: Label 'No new item tracking information provided.'; trigger OnInitReport() begin IsReclassSpecific := true; ShouldPostLater := true; ShouldPostNow := false; end; trigger OnPreReport() begin if (NewLotNo = '') and (NewSerialNo = '') and (NewPackageNo = '') and (NewExpirationDate = 0D) then Error(NoItemTrackingChangesErr); end;}